sigma cp

Free PDF manuals for the Kentec Sigma CP — the current conventional fire alarm panel from Kentec, available in 2-zone, 4-zone and 8-zone variants. The Sigma CP is the standard Kentec choice for sites where conventional zone-level detection is acceptable: small retail, hospitality, churches, community buildings and small offices.

Kentec Sigma CP Conventional Fire Panel Manual

Available manuals

About the Sigma CP

The Sigma CP is EN 54-2 and EN 54-4 certified and provides full BS 5839-1 compliance. It is the modern Kentec conventional platform that replaced the legacy K3000. Key features:

  • 2, 4 and 8-zone variants covering small to medium conventional installations
  • Conventional 2-wire detection circuits with end-of-line monitoring
  • Two monitored sounder circuits (NACs)
  • Volt-free fire and fault relay outputs
  • Walk test mode for one-engineer commissioning
  • Zone disable / re-enable for managed isolations
  • Front-panel keyswitch for engineering access
  • EN 54 compliant battery charging

Where the Sigma CP fits

For sites needing addressable detection rather than zone-level conventional, see the Kentec Syncro AS or Syncro Lite ranges instead. For extinguishant release applications, see the Sigma XT range.

Sigma CP installation training

BH Courses run a structured Kentec fire alarm course that includes Sigma CP commissioning workflows alongside the addressable Kentec range. For multi-brand fire alarm training, see the Fire Alarm Training Course.

Display:

Kentec Sigma CP Conventional Fire Alarm Panel Manual

The Sigma CP Manual is the Kentec reference for installing, commissioning and operating the Sigma CP conventional fire alarm panel range — available in 2-zone, 4-zone and 8-zone variants. The Sigma CP is the standard Kentec choice for conventional fire detection in small-to-medium UK commercial buildings.

What the manual covers

  • 2-zone, 4-zone and 8-zone variant configuration
  • Cabinet mounting, AC mains wiring, earthing
  • Battery sizing for 24h standby + 30 min alarm
  • Conventional 2-wire zone topology with EOL monitoring
  • Smoke and heat detector wiring
  • Manual call point (MCP) wiring and zone allocation
  • Two monitored sounder circuits (NACs)
  • Volt-free fire and fault relay outputs
  • Walk test mode for one-engineer commissioning
  • Zone disable and re-enable workflows
  • Common fault diagnostics

Who should use this manual

This manual is for fire alarm installers and commissioning engineers deploying Sigma CP panels on small-to-medium conventional installations. The Sigma CP is straightforward to commission and is suited to electricians moving into fire alarm work.

Where the Sigma CP fits

The Sigma CP is ideal for sites needing zone-level detection: small offices, retail, restaurants, churches, care homes. For addressable detection, see the Syncro AS or Syncro Lite.

Kentec Sigma CP training

BH Courses run a structured Kentec fire alarm course that includes Sigma CP commissioning workflow alongside the addressable Kentec range.

×